- put file name in Sqlite connect string in quotes
- improvements to Mediatek Philips 120+125/Sony serializer (physically reorder XML nodes, use flags stored in Java serialized blob)
- selecting a RefList changed the current working directory, which prevented .ini files to be found by loaders
- downgraded SQLite libraries to avoid a memory access violation crash in the SQLitePCL.raw 2.1.10 (causing at least Panasonic lists to crash on load)
- added support for \*.dbm files with size 782536 (e.g. Vantage VT-80 HD)
- moved "Save as..." and "Export reference list" to a sub menu as they caused frequent confusion with the regular "Save".
- added support for Grundig dtv_cmdb_3.bin channel lists with size of 1270 KB
- fixed saving of Grundig dtv_cmdb_3.bin channel lists with size of 1293 KB
- updated tivusat reference list
- fixed issue when saving *cmdb_*.bin channel lists after applying a reference list which contains missing channels
- HB_DATABASE_mm_dd.DBM for Strong SRT 7007: added option "reorderPhysically" in ChanSort.Loader.DBM.ini
for this particular format to not only change the number but also change the order or data records in the file
- removed app.config files containing assembly redirects from projects and included them in the central Solution.props instead
- upgraded various NuGet packages
- experimental support for MtkChannelList.xml (which is part of several MediaTek based Google TVs, e.g. Philips formats 120 and 125)
- Philips formats 100-125: improved decoding of non-latin characters (turkish, cyrillic, ...)
- added support for dtv_cmdb_3.bin file with file size 1323920
- fixed error when opening reference list dialog with Italian translation
- "Tornado" TV lists which are a slight variation of old Philips lists using a file name __chtb_do_not_delete_.xml
- fixed issues where SQLite database files didn't get unlocked after saving
- fixed quirks with missing e_sqlite3.dll when running unit tests with Resharper
- upgraded to latest Sqlite libraries to support ARM
- finished implementation for Hisense Vidaa U5.2 file format (using servicelist.db with renamed tables and columns)
- Philips: show info that it may be necessary to unplug and reboot the TV after the import
- Philips ChannelMap_45: show info when there are checksum errors, which indicate that TV's internal list is broken
and a rescan is required in order to properly export/import the list.
- Philips: fixed display of symbol rate and frequency (off by factor 1000 depending of list and DVB source)
- Philips: fixed special characters in channel names (e.g. german umlauts)
- Philips: "ServiceType" now only shows "TV" or "Radio". There is no information about HD/SD in the file.